Search results for "Contrast injection"

showing 3 items of 3 documents

Kardiale MRT : Änderungen der normalisierten myokardialen Gadolinium-Anreicherung über die Zeit nach Kontrastmittelinjektion in Patienten mit akuter …

2011

PURPOSE An increased normalized gadolinium accumulation (NGA) in the myocardium during early washout has been used for the diagnosis of acute myocarditis (AM). Due to the fact that the pharmacokinetics of contrast agents are complex, time-related changes in NGA after contrast injection are likely. Because knowledge about time-related changes of NGA may improve the diagnostic accuracy of MR, our study aimed to estimate the time course of NGA after contrast injection in patients as well as in healthy volunteers. MATERIALS AND METHODS An ECG-triggered inversion recovery SSFP sequence with incrementally increasing inversion times was repetitively acquired over the 15 minutes after injection of …

AdultGadolinium DTPAMalemedicine.medical_specialtymedia_common.quotation_subjectGadoliniumCardiac-Gated Imaging TechniquesMedizinchemistry.chemical_elementContrast MediaSensitivity and SpecificityPharmacokineticsReference ValuesInternal medicineHealthy volunteersmedicineImage Processing Computer-AssistedContrast (vision)HumansRadiology Nuclear Medicine and imagingIn patientMuscle Skeletalmedia_commonbusiness.industryMyocardiumWashoutSteady-state free precession imagingMiddle AgedImage EnhancementMagnetic Resonance ImagingMyocardial ContractionMyocarditischemistryContrast injectionAcute DiseaseInjections IntravenousCardiologyFemalebusiness
researchProduct

Kontrastmittel-Kurzinfusion oder -Bolusinjektion bei der i.v. Urographie

1993

The rate of contrast injection during i.v. urography may vary considerably (bolus injection or drip infusion). The effect of 5 rates of injection (6, 12, 18, 36 and 72 ml/min) on the contrast density in the renal collecting system was examined over a period of 30 minutes. Measurements showed an inter-individual difference of more than 200% in each group. The intra-individual variations for different rates of injection were very slight; individual concentration in the kidney for a given dose depends only slightly on the rate of injection. There is no statistically significant improvement in contrast values as a result of a bolus injection. The reduced incidence of side effects justifies the …

Kidneymedicine.diagnostic_testbusiness.industryComputed tomographyCollection systemContrast mediumBolus (medicine)medicine.anatomical_structureContrast injectionmedicineRadiology Nuclear Medicine and imagingbusinessNuclear medicinePyelogramBolus injectionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Technique of CT and MR Examinations

1989

The three original groups participating in our study used the EMI Mark I scanner from 1975 to the middle of 1977 and the EMI CT 1010 scanner after mid-1977. The Siemens Somatom DR has been used in Augsburg and Berlin since 1983, and the Philips Tomoscan CT 350 in Mainz since mid-1986.

Scannerbusiness.industryContrast injectionMedicineNuclear medicinebusiness
researchProduct